High-temperature meters with factory connection (model code I)Figure 1-3:
The transmitter is shipped with a flexible connection factory installed between the sensor and the
transmitter. The transmitter must be dismounted from its shipping location (spot-welded to the sensor
case) and then mounted separately. Power supply and I/O must be field wired to the transmitter.
A
B
C
A. Sensor
B. Transmitter or core processor
C. Factory-installed flexible connection
4-wire remote installation for Coriolis meters (model code R or M)Figure 1-4:
The transmitter is installed remotely from the sensor. The 4-wire connection between the sensor and
transmitter must be field wired. Power supply and I/O must be field wired to the transmitter.
A
A
B
C
D
A. Transmitter
B. Field-wired 4-wire connection
C. Core processor
D. Sensor
Planning
Installation Manual 3