EasyManua.ls Logo

Emerson MICRO MOTION 2700 - Status LED States; Status Alarms

Emerson MICRO MOTION 2700
374 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.1 Status LED states
The status LED on the transmitter indicates whether or not alarms are active. If alarms are
active, view the alarm list to identify the alarms, then take appropriate action to correct
the alarm condition.
Your transmitter has a status LED only if it has a display.
If the transmitter has a display and LED Blinking is disabled, the status LED does not flash to
indicate an unacknowledged alarm.
Status LED statesTable 12-1:
Condition LED Blinking parameter LED behavior
Normal operation (no alarm) N/A Solid green
Unacknowledged corrected condition (no
alarm)
Enabled Flashing green
Disabled Solid green
Acknowledged low-severity alarm (outputs con-
tinue to report process data)
N/A Solid yellow
Unacknowledged low-severity alarm (outputs
continue to report process data)
Enabled Flashing yellow
Disabled Solid yellow
Acknowledged high-severity alarm (outputs in
fault)
N/A Solid red
Unacknowledged high-severity alarm (outputs
in fault)
Enabled Flashing red
Disabled Solid red
12.2 Status alarms
Status alarms and recommended actionsTable 12-2:
Alarm code Description Recommended actions
A001 EEPROM Error (Core Processor) The transmitter has detected a problem communicating with
the sensor. You can try cycling power to the meter to see if the
condition clears. If not, the core processor must be replaced.
A002 RAM Error (Core Processor) The transmitter has detected a problem communicating with
the sensor. You can try cycling power to the meter to see if the
condition clears. If not, the core processor must be replaced.
Troubleshooting