System Application Guide SAG582127000
Spec. No. 582127000 (Model 721
NPBB) Issue AF, February 26, 2014
Page 15 of 125
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
c) Order a module mounting position blank cover panel, P/N 21140440, for each empty module
mounting position in the system, as desired.
4) 588705000 Converter Option: Order interface components for module mounting shelf(s) Spec. No.
588705000 as required per List 34. Order field expansion module mounting shelf(s) per List 35. Order
module mounting shelf(s) per PD588705000 (choices are 58870500040, 58870500041, 58870500042).
a) Order the front access DC Input Termination Assembly per List 45, 46, or 47 if module mounting shelf
58870500040 ordered (or order module mounting shelves with terminal blocks, 58870500041,
58870500042).
b) Order converter modules as required, P/N 1C400483500E.
c) Order a module mounting position blank cover panel, P/N 21140440, for each empty module
mounting position in the system, as desired.
5) 588705300 Rectifier/Converter Option: Order interface components for module mounting shelf(s) Spec.
No. 588705300 as required per List 32. Order field expansion module mounting shelf(s) per List 33.
Order module mounting shelf(s) per PD588705300.
a) Order the front access AC Input Termination Assembly per List 40, 41, or 42 (or order module
mounting shelves with AC input cable assemblies, see PD588705300).
b) Order rectifier modules as required, P/N 1R482000E3.
c) Order optional converter interface components per List 60.
d) Order optional DC-DC converter modules as required, P/N 1C48241500.
6) Order battery trays as required per List 93.
a) Order batteries as required per “Batteries” under ACCESSORY DESCRIPTIONS.
b) Order “Optional Battery Tray Battery Disconnect Circuit Breaker and Housing Kits” as required.
c) Order “Optional Battery Tray Front Battery Cover Kits” as required.
List 4: Distribution Only Bay Distribution Cabinet Bottom Rear Cover
Features
Bottom rear cover shield for use when a
supplemental bay is configured for
“distribution only” (no module mounting
shelf).
Restrictions
Module mounting shelf(s) cannot be mounted in
a bay when List 4 is installed.
Ordering Notes
1) Order when a supplemental distribution bay is configured for “distribution only” (no module mounting
shelf).
List 5: 1
st
Supplemental Bay Common Equipment (Power and Distribution or Distribution Only),
Located Remote from Main Bay
Features
Provides common equipment for one remote “power and distribution or distribution only” bay rated for up
to 2000 amperes of distribution. Includes interbay communications cabling.
Accepts one (1) distribution cabinet (options are 1-row, 2-row, 3-row, or 4-row cabinet).
Includes SM-DU (provides bay interface to ACU+ Controller).
Accepts up to six (6) module mounting shelves Spec. No. 588705000 (including expansion shelves).
or
Accepts up to six (6) module mounting shelves Spec. No. 588705300 (including expansion shelves).