Product matrix - OCX 8800 (continued)Table 1-1:
Code Probe mounting assembly
10 (ANSI 2 in. 150 lb) 6 in. diameter flange. 4.75 in. BC with 4 x
0.75 in. diameter holes - standard O
2
cell
20 (DIN) 185 mm diameter flange, 145 mm BC with 4 x 18 mm
diameter holes - standard O
2
cell
21 (DIN) 185 mm diameter flange, 145 mm BC with 4 x 18 mm
diameter holes -high sulfur O
2
cell
Code Mounting hardware - stack side
0 No adapter plate (0 must be chosen under Mounting adapter -
probe side below)
1 New installation - square weld plate with studs
2 Model 218/240 mounting plate (with model 218/240 shield
removed)
3 Existing model 218/240 support shield
4 Competitor's mount
5 Model 132 adapter plate
Code Mounting hardware - probe side
0 No adapter plate
1 Probe only (ANSI)
4 Probe only (DIN)
Code
Electronics housing - NEMA 4X, IP66 HART communica-
tions
H1 HART communications - basic unit
H2 HART communications - local operator interface
H3 HART communications - calibration solenoids
H4 HART communications - local operator interface and calibra-
tion solenoids
F1 Fieldbus communications - basic unit
F2 Fieldbus communications - local operator interface
F3 Fieldbus communications - calibration solenoids
F4 Fieldbus communications - local operator interface and cali-
bration solenoids
Code Electronics mounting
01 Integral to sensor housing electronics
02 Split architecture with no cable
Code In-situ filter
0 None
2 High surface area stainless steel
Description and specifications