Do you have a question about the Emerson Rosemount OCX8800 and is the answer not in the manual?
Brand | Emerson |
---|---|
Model | Rosemount OCX8800 |
Category | Transmitter |
Language | English |
Explains the purpose of the safety alert symbol used for hazard communication.
Defines DANGER, WARNING, CAUTION, and NOTICE used for hazard communication.
Highlights critical instructions and warnings for safe product installation and operation.
Outlines the manual's scope and advises user familiarization for proper operation.
Defines WARNING, CAUTION, and NOTE used throughout the publication for hazard communication.
Provides notes on illustration numbering and general manual usage for safety and performance.
Lists items typically included in the transmitter package for verification.
Provides a general understanding of the transmitter's scope and functionality.
Details the technical specifications of the transmitter, including ranges and limits.
Details product model codes, options, and configurations for ordering.
Lists essential safety precautions for installation and operation.
Covers procedures for selecting a location and mounting the transmitter.
Details wiring requirements and connections for power and communication.
Describes pneumatic system connections for reference air, calibration, and blowback.
Provides initial startup procedures and cautions for the transmitter.
Ensures correct mechanical and electrical installation before startup.
Outlines steps for powering up the transmitter and initial operating temperature.
Details how to set test gas values for calibration using HART or Fieldbus.
Explains how to configure calibration solenoids for automatic calibration.
Describes the blowback feature and its configuration for cleaning filters.
Explains how to verify analyzer readings using calibration gases.
Describes the feature that fails calibration if values are outside tolerances.
Details the feature to periodically flood the COe sensor with air for calibration.
Provides procedures for resetting the device in case of faults or alarms.
Introduces the LOI module for installation and operation.
Explains how to orient the LOI module for user convenience.
Describes the LOI assembly, keys, and functions for user interaction.
Explains the calibration process and methods available for the transmitter.
Details how to set up automatic calibration using HART.
Describes how an operator can initiate an automatic calibration.
Provides procedures for manual O2, COe, or combined calibration using the LOI or HART.
Explains the O2 and COe D/A trim procedures using the LOI.
Details O2 and COe D/A trim procedures using HART communicator.
Introduces the 375 Field Communicator as an interface device.
Covers connections for HART and Fieldbus segments.
Explains how to operate the Field Communicator off-line and on-line.
Provides the menu structure for HART communication.
Provides the menu structure for Fieldbus communication.
Introduces Foundation Fieldbus as a digital communication system.
Describes the role and types of function blocks in Fieldbus devices.
Explains how transducer blocks connect function blocks to I/O.
Details Fieldbus network concepts like Link Active Scheduler (LAS).
Lists OCX implemented function blocks such as AI, PID, ARTHM, ISEL.
Describes the AI function block, its parameters, and application examples.
Details the PID block, its equations, modes, and application examples.
Explains the ARTHM block for range extension and compensation.
Describes the ISEL block for selecting input values.
Covers how to integrate the analyzer with DeltaV software.
Introduces methods for identifying and isolating faults in the transmitter.
Explains the alarm relay and diagnostic signals.
Provides a guide to identifying probable causes and corrective actions for faults.
Provides general procedures for maintaining and servicing the transmitter.
Details procedures for removing and installing the transmitter.
Outlines disassembly and reassembly of the sensor housing for component replacement.
Details disassembly and reassembly of the electronics housing for component replacement.
Covers the assembly steps for the electronics housing components.
Explains how to replace clogged or damaged tube fittings.
Lists parts for the sensor housing with diagrams and part numbers.
Lists parts for the electronics housing with diagrams and part numbers.
Lists parts for the O2 cell and heater strut assembly.
Provides general safety instructions for wiring and installation, especially for EU member states.
Introduces the SPA with HART Alarm option for the transmitter.
Describes the SPA's functionality and connection to the OCX 8800.
Provides typical interface connections for the SPA and OCX 8800.
Details configuring SPA operating parameters via menu and calibration.
Provides procedures for returning material for repair or service.
An alphabetical index of topics covered in the manual.