Instruction Manual
IM-106-880C, OI
Section 1: Description and
Specifications
April 2017
Product Matrix - Hazardous Area OCX
8800
15
1.5 Product Matrix - Hazardous Area OCX 8800
Table 1-1 Product Matrix - Hazardous Area OCX 8800
OCX88CO
2
/Combustibles Transmitter - Flameproof
Code
Probe Length and Material
00
No Probe or Exhaust Tube
11
18 in. (457 mm) 316 SST up to 1300°F (704°C)
12
3 ft (0.91 m) 316 SST up to 1300°F (704°C)
13
6 ft (1.83 m) 316 SST up to 1300°F (704°C)
14
9 ft (2.7 m) 316 SST up to 1300°F (704°C)
21
18 in. (457 mm) Inconel 600up to 1832°F (1000°C)
22
3 ft (0.91 m) Inconel 600up to 1832°F (1000°C)
23
6 ft (1.83 m) Inconel 600 up to 1832°F (1000°C)
24
9 ft (2.7 m) Inconel 600up to 1832°F (1000°C)
31
18 in. (457 mm) Ceramic up to 2600°F (1427°C)
32
3 ft (0.91 m) Ceramic up to 2600°F (1427°C)
Code
Probe Mounting Assembly
10
(ANSI 2 in. 150 lb) 6" dia. flange, 4.75" BC with 4 x 0.75" dia. holes - Standard O2 Cell
11
(ANSI 2 in. 150 lb) 6" dia. flange, 4.75" BC with 4 x 0.75" dia. holes - High Sulfur O2 Cell
20
(DIN) 185 mm dia. flange, 145 mm BC with 4 x 18 mm dia. holes - Standard O2 Cell
21
(DIN) 185 mm dia. flange, 145 mm BC with 4 x 18 mm dia. holes - High Sulfur O2 Cell
Code
Mounting Hardware - Stack Side
0
No Adapter Plate (“0” must be chosen under “Mounting Adapter - Probe Side” below)
1
New Installation - Square weld plate with studs
2
Model 218/240 Mounting Plate (with Model 218/240 Shield Removed)
3
Existing Model 218/240 Support Shield
4
Competitor’s Mount
(1)
5
Model 132 Adapter Plate
Code
Mounting Hardware - Probe Side
0
No Adapter Plate
1
Probe Only (ANSI)
4
Probe Only (DIN)
Code
Electronics Housing - NEMA 4X, IP66 HART Communications
H1
HART Communications - Basic Unit
H2
HART Communications - Local Operator Interface
H3
HART Communications - Calibration Solenoids
H4
HART Communications - Local Operator Interface and Calibration Solenoids
F1
Fieldbus Communications - Basic Unit
F2
Fieldbus Communications - Local Operator Interface
F3
Fieldbus Communications - Calibration Solenoids
F4
Fieldbus Communications - Local Operator Interface and Calibration
Solenoids
Code
Electronics Mounting
01
Integral to Sensor Housing Electronics
02
Split Architecture with no cable
OCX88C
11
10
1
1
H3
01
Example