6.3 Parameter descriptions
6.3.1 Pr mm.000
Pr mm.000 is available in all menus, commonly used functions are provided as text strings in Pr mm.000 shown in Table 6-1. The functions in Table
6-1 can also be selected by entering the appropriate numeric values (as shown in Table 6-2) in Pr mm.000. For example, enter 4001 in Pr mm.000 to
store drive parameters on an NV media card.
Table 6-1 Commonly used functions in xx.000
Table 6-2 Functions in Pr mm.000
* See Chapter 9 NV Media Card on page 40 for more information on these functions.
** These functions do not require a drive reset to become active.
All other functions require a drive reset to initiate the function. Equivalent values and strings are also provided in the table above.
Value Equivalent value String Action
00
None No action
1001 1
SAVE Save drive parameters to non-volatile memory
6001 2
LOAd.1
Load the data from file 1 on a non-volatile media card into the drive provided it is a
parameter file
4001 3
SAVE.1 Store the drive parameters in file 1 on a non-volatile media card
6002 4
LOAd.2
Load the data from file 2 on a non-volatile media card into the drive provided it is a
parameter file
4002 5
SAVE.2 Store the drive parameters in file 2 on a non-volatile media card
6003 6
LOAd.3
Load the data from file 3 on a non-volatile media card into the drive provided it is a
parameter file
4003 7
SAVE.3 Store the drive parameters in file 3 on a non-volatile media card
12000 8
diff.d Only display parameters that are different from their default value
12001 9
dest Only display parameters that are used to set-up destinations
1233 10
def.50 Load 50 Hz defaults
1244 11
def.60 Load 60 Hz defaults
Value Action
1000 Save parameters when Under Voltage Active (Pr 10.016) is not active.
1001 Save parameters under all conditions
1233 Load standard (50 Hz) defaults
1244 Load US (60 Hz) defaults
1299 Reset {St.HF} trip.
2001* Create a boot file on a non-volatile media card based on the present drive parameters
4yyy* NV media card: Transfer the drive parameters to parameter file yyy
6yyy* NV media card: Load the drive parameters from parameter file yyy
7yyy* NV media card: Erase file yyy
8yyy* NV Media card: Compare the data in the drive with file yyy
9555* NV media card: Clear the warning suppression flag
9666* NV media card: Set the warning suppression flag
9777* NV media card: Clear the read-only flag
9888* NV media card: Set the read-only flag
12000** Only display parameters that are different from their default value. This action does not require a drive reset.
12001** Only display parameters that are used to set-up destinations (i.e. DE format bit is 1). This action does not require a drive reset.