EasyManua.ls Logo

Endress+Hauser Deltapilot M FMB50 - Page 5

Endress+Hauser Deltapilot M FMB50
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Deltapilot M FMB50/51/52/53
Endress+Hauser 5
FMB50/51/52 universal application
Modular probe program to ensure optimum process adaptation
FMB50 compact version: installation in the tank from below or from the side
FMB51/52 rod and cable extension: installation from above, i.e. easy to retrofit ground tanks, no additional
opening in the tank floor
FMB50 optimized for the food-processing and pharmaceutical industry
All typical flush-mounted process connections can be supplied
Welding flanges
Stainless steel housing
All the sanitary process connections are gap-free and can be cleaned so that the unit is free of residue, e.g.
CIP cleaning
USDA/H1-approved transfer liquid as per FDA Directive
3A approval or EHEDG approvals
P01-DB5xxxxx-12-xx-xx-xx-004
FMB53 for level measurement in water and wastewater
The housing with the electronic insert is mounted outside shafts and tanks in such a way that it is protected
from flooding. The extension cable is secured with a suspension clamp.
The measuring cell tube made of stainless steel (AISI 316L) and the Alloy process isolating diaphragm allow
use in aggressive media such as wastewater for example.
Extension cable up to 400 m (1312 ft) in length (up to 100 m (328 ft) in Ex-areas) without strain relief.
Special measuring cell with gold/rhodium coating for applications in which severe hydrogen formation can
occur (e.g. digested sludge); ä 26.
Special measuring cell with gold/platinum coating for acids, alkalis or sea water; ä 26.
74 -74 -
TYPE EL
February 2010

Table of Contents

Other manuals for Endress+Hauser Deltapilot M FMB50

Related product manuals