Deltapilot M FMB50/51/52/53
52 Endress+Hauser
Certificates and approvals
CE mark The device meets the legal requirements of the relevant EC directives.
Endress+Hauser confirms that the device has been successfully tested by applying the CE mark.
Ex approvals •ATEX
•FM
•CSA
Also combinations of different approvals
All explosion protection data are given in separate documentation which is available upon request. The Ex
documentation is supplied as standard with all devices approved for use in explosion hazardous areas.
ä 66 ff, "Safety Instructions" and "Installation/Control Drawings" sections.
Suitability for hygienic
processes
Functional safety SIL The Deltapilot M with 4 to 20 mA output signal has been developed to assessed and certified by TÜV NORD
CERT as per IEC 61508 Edition 2.0 and IEC 61511. These devices can be used to monitor the process level
and pressure up to SIL 2.
For a detailed description of the safety functions with Deltapilot M, settings and functional safety data, see the
"Functional safety manual - Deltapilot M" SD00347P. Ordering Information ä 53 ff, feature 590
"Additional Approval:" version LA "SIL".
Pharma (CoC) Certificate of Compliance (CoC) (according to ASME BPE-2007)
See "Ordering information", ä 53 ff, feature 590 "Additional Option:", option"LW".
Standards and guidelines DIN EN 60770 (IEC 60770):
Transmitters for use in industrial process control systems
Part 1: Methods for inspection and routine testing
DIN 16086:
Electrical pressure measuring instruments, pressure sensors, pressure transmitters, pressure measuring
instruments,
concepts, specifications on data sheets
EN 61326 series:
EMC product family standard for electrical equipment for measurement, control and laboratory use.
Pressure Equipment Directive
(PED)
The Deltapilot M device corresponds to Article 3 (3) of the EC directive 97/23/EC (Pressure Equipment
Directive) and has been designed and manufactured according to good engineering practice.
Drinking water approval KTW certificate
NSF 61 approval
ACS approval
North-American practice for
installation of process seals
Endress+Hauser instruments are designed according to ANSI/ISA 12.27.01 either as single seal or dual seal
devices with annunciation, allowing the user to waive the use and save the cost of installing external secondary
process seals in the conduit as required by the process sealing sections of ANSI/NFPA 70 (NEC) and CSA 22.1
(CEC). These instruments comply with the North-American installation practice and provide a very safe and
cost-saving installation for pressurized applications with hazardous fluids.
Further information can be found in the control drawings of the relevant devices.
The Deltapilot M is suitable for use in hygienic processes.
Overview of permitted process connections from ä 30.
Many versions meet the requirements of 3A-Sanitary Standard No. 74 and
are certified by the EHEDG.
Suitable fittings and seals must be used for hygienic design in accordance
with 3A and EHEDG specifications.
Note!
Gap-free connections can be cleaned
without residue using the usual cleaning methods.
TYPE EL
February 2010