EasyManua.ls Logo

Endress+Hauser Levelflex FMP54 - Page 121

Endress+Hauser Levelflex FMP54
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP51, FMP52, FMP54
Endress+Hauser 121
Remote display FHX50
Accessory Description
Remote display FHX50
A0019128
Material:
Plastics PBT
316L
Ingress protection: IP68 / NEMA 6P and IP66 / NEMA 4x
Suitable for the display modules:
SD02 (push buttons)
SD03 (touch control)
Connection cable:
Cable with M12 plug; supplied with the FHX50; up to 30 m (98 ft)
Customer supplied standard cable; up to 60 m (196 ft)
Ambient temperature: –40 to 80 °C (–40 to 176 °F)
If the remote display is to be used, the device must be ordered in the version "Prepared for display FHX50"
(feature 030, option L or M). For the FHX50, on the other hand, the option A: "Prepared for display FHX50" has
to be selected in feature 050: "Option Measurement Device".
If a device has not been ordered in the version "Prepared for display FHX50", but is nevertheless to be equipped
with an FHX50, it is essential to select the option B: "Not prepared for display FHX50" in feature 050: "Option
Measurement Device" of the FHX50. In this case, a retrofit kit, needed to prepare the device for the remote
display, is supplied together with the FHX50.
For transmitters with approval, application of the FHX50 may be restricted. A device may only be retrofitted with
the FHX50 if option L or M ("Prepared for FHX50") is quoted under Basic specifications, position 4 "Display,
operation" in the associated Safety Instructions (XA).
In addition to this, observe the Safety Instructions (XA) of the FHX50.
Do not retrofit transmitters with:
approval for use in areas with combustible dusts (Dust-Ex approval)
type of protection Ex nA
For details refer to the document SD01007F.

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP54

Related product manuals