EasyManua.ls Logo

Endress+Hauser Levelflex FMP55 - Page 45

Endress+Hauser Levelflex FMP55
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP55
Endress+Hauser 45
Special mounting conditions
Bypasses and stilling wells
In bypass and stilling well applications it is recommended to use a centering disks or stars.
A B
³100
(3.94)
3
21
A0014129
1 Mounting in a stilling well
2 Mounting in a bypass
3 Minimum distance between end of probe and lower edge of the bypass; see table below
Minimum distance between end of probe and lower edge of the bypass
Type of probe Minimum distance
Rope 10 mm (0.4 in)
Rod 10 mm (0.4 in)
Coax 10 mm (0.4 in)
Pipe diameter: > 40 mm (1.6") for rod probes
Rod probe installation can take place up to a diameter size of 150 mm (6 in). In the event of larger
diameters, a coax probe is recommended.
Side disposals, holes or slits and welded joints that protrude up to approx. 5 mm (0.2") inwards do
not influence the measurement.
The pipe may not exhibit any steps in diameter.
The probe must be 100 mm longer than the lower disposal.

Table of Contents

Other manuals for Endress+Hauser Levelflex FMP55