EasyManua.ls Logo

Endress+Hauser Micropilot FMR10 - 5.2 Post-installation check

Endress+Hauser Micropilot FMR10
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR10
Endress+Hauser 19
Process
Process temperature, process
pressure
p
-40
+60 ( 40)+1
0 ( )+32
T
p
[ °F ]°C ( )
-1( )-14.5
0
[bar ](psi)
3 (43.5)
A0030443-EN
 18 FMR10: Permitted range for process temperature and process pressure
Process temperature range
–40 to +60 °C (–40 to +140 °F)
Process pressure range
p
rel
= –1 to 3 bar (–14.5 to 43.5 psi)
p
abs
< 4 bar (58 psi)
Dielectric constant
For liquids
ε
r
≥ 4
Contact Endress+Hauser for lower ε
r
values
For dielectric constants (DC values) of many media commonly used in various industries refer
to:
the Endress+Hauser DC manual (CP01076F)
the Endress+Hauser "DC Values App" (available for Android and iOS)
Mechanical construction
Dimensions 40 mm (1.5 in) antenna
G 1 1/2"
20 (0.79)
G 1"
NPT 1"
26 (1.02)
ø75 (2.95)
28 (1.1)
140 (5.5)
112 (4.4)
NPT 1 1/2"
A
B
A0028805
 19 Dimensions of G 1-1/2" or MNPT 1-1/2" process connection thread, engineering unit: mm (in)
A Cable gland
B FNPT 1/2“ conduit

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR10