Micropilot FMR60, FMR62, FMR67 XA01555F-A
Endress+Hauser 19
Position 11-13 (Process Connection)
Selected option Description
FMR60 GGJ Thread ISO228 G1-1/2, 316L
RGJ Thread ANSI MNPT1-1/2, 316L
XxG Flange (different sizes), PP
XxJ Flange (different sizes), 316L
FMR62 AxK Flange (different sizes), PTFE>316/316L
CxK Flange (different sizes), PTFE>316L
GxJ Thread ISO (different sizes), 316L
KxK Flange (different sizes), PTFE>316L
MxK Slotted-nut (different sizes), PTFE>316L
RxJ Thread ANSI (different sizes), 316L
TxK Tri-Clamp (different sizes), PTFE>316L
FMR67 AxJ Flange (different sizes), 316/316L
CxJ Flange (different sizes), 316L
GGJ Thread ISO228 G1-1/2, 316L
KxJ Flange (different sizes), 316L
RGJ Thread ANSI MNPT1-1/2, 316L
XxA Align. device (different sizes)
XxG Flange (different sizes), PP
XxJ Flange (different sizes), 316L
Position 14 (Air Purge Connection)
Selected option Description
FMR67 A W/o
1 G1/4
2 NPT1/4
Optional specifications
ID Nx (Accessory Mounted)
Selected option Description
FMR6x NA Overvoltage protection
Safety instructions: General
• Staff must meet the following conditions for mounting, electrical installation, commissioning and
maintenance of the device:
– Be suitably qualified for their role and the tasks they perform
– Be trained in explosion protection
– Be familiar with national regulations
• Install the device according to the manufacturer's instructions and national regulations.
• Do not operate the device outside the specified electrical, thermal and mechanical parameters.
• Only use the device in media to which the wetted materials have sufficient durability.
• Avoid electrostatic charging:
– Of plastic surfaces (e.g. housing, sensor element, special varnishing, attached additional
plates, ..)
– Of isolated capacities (e.g. isolated metallic plates)