9. Appendix
9.1 Accessories
The following accessories for Mycom
CLM 121/151 can be ordered separately:
• Weather protection cover CYY 101
Weather protection cover for installation on
Mycom CLM 121/151;
Dimensions: 320 x 300 x 300 mm (L x W x D)
Material: stainless steel
(Order no. CYY 101)
• Post mounting kit
Retrofit kit for mounting of Mycom CLM 151
to horizontal or vertical tubing
(max. Ø 70 mm)
Material: galvanized steel
(Order no. 50062121)
• Upright post VM3
For post mounting of Mycom CLM 151
Material: hot-dip galvanized steel
(Order no. 50003248)
• Junction box VS
Junction box with plug-in socket and
connector type SXP for pluggable connection
between conductivity measuring cell and
connecting line to the instrument.
Suitable for all measuring cells and for
connection of special measuring cables SMK,
KMK (for cells with automatic temperature
compensation) or DMK.
Dimensions:
– without SXP connector:
82 x 80 x 55 mm (L x W x H)
– with SXP connector:
160 x 80 x 55 mm (L x W x H)
Material: plastic
Ingress protection: IP 65
(Order no. 50001054)
• Flat packing
To seal the panel cutout of Mycom CLM 151
for panel mounting
(Order no. 50064975)
• Conductivity measuring cable KMK
Combination measuring cable for
2-electrode conductivity measuring cells
when instrument is equipped for
temperature compensation or temperature
measurement; Pt 100 3-wire connection is
required.
Low-noise coaxial cable with 6 auxiliary
cores (0.5 mm
2
each) and outer screen in
PVC sheath;
Cable diameter: 10.5 mm
Length: min. 5 m
(Order no. 50001419)
• Conductivity measuring cable SMK
Special measuring cable for connection of
2-electrode conductivity measuring cells to
measuring instruments.
Suitable for all measuring cells without
temperature sensor;
Length: min. 5 m
(Order no. 50000598)
• Conductivity measuring cable CYK 7
Special measuring cable for connection of
conductivity measuring cells with temperature
sensor with the Mycom CLM 151 instrument;
consisting of a coaxial line in low-noise quality
and 3 auxiliary cores (0.75 mm
2
each) with
common screen;
Outer diameter: 7 mm
Length: min. 5 m
(Order no. 50041101)
• 2-electrode conductivity measuring cells
CLS 10 to CLS 30
For detailed information please refer to the
separate Technical Information:
– CLS 12 TI 082C/07/e
– CLS 15 TI 109C/07/e
– CLS 19 TI 110C/07/e
– CLS 20 TI 084C/07/e
– CLS 21 TI 085C/07/e
– CLS 30 TI 086C/07/e
Supplementary documentation
Operating instructions
Mycom instrument family serial interface
BA 090C/07/en (order no. 50059856)
9. Appendix
mycom CLM 121 / 151 - CD/MM
64