Installation Proline Promag 50
24 Endress+Hauser
2.5.3 Installing the high-temperature version (with PFA lining)
The high-temperature version has a housing support for the thermal separation of sensor and
transmitter. The high-temperature version is always used for applications
in which high ambient temperatures are encountered in conjunction with high fluid
temperatures. The high-temperature version is obligatory if the fluid temperature exceeds
+150 °C.
!
Note!
You will find information on permissible temperature ranges in the Operating Instructions of the
CD-ROM
Insulation
Pipes generally have to be insulated if they carry very hot fluids, in order to avoid energy losses
and to prevent accidental contact with pipes at temperatures that could cause injury. Guidelines
regulating the insulation of pipes have to be taken into account.
"
Caution!
Risk of measuring electronics overheating. The housing support dissipates heat and its entire
surface area must remain uncovered. Make sure that the sensor insulation does not extend past
the top of the two sensor shells.
A0004300