2.5.4 Tightening torques for threaded fasteners (Promag P)
Please note the following:
The tightening torques listed below are for lubricated threads only.
Always tighten the screws uniformly and in diagonally opposite sequence.
Overtightening the screws will deform the sealing faces or damage the seals.
The tightening torques listed below apply only to pipes not subjected to tensile stress.
Promag P tightening torques for EN (DIN)
Nominal diameter EN (DIN) Threaded
fasteners
Max. tightening torque [Nm]
[mm] Pressure rating [bar] PTFE PFA
15 PN 40 4 × M 12 11
25 PN 40 4 × M 12 26 20
32 PN 40 4 × M 16 41 35
40 PN 40 4 × M 16 52 47
50 PN 40 4 × M 16 65 59
65 * PN 16 8 × M 16 43 40
65 PN 40 8 × M 16 43 40
80 PN 16 8 × M 16 53 48
80 PN 40 8 × M 16 53 48
100 PN 16 8 × M 16 57 51
100 PN 40 8 × M 20 78 70
125 PN 16 8 × M 16 75 67
125 PN 40 8 × M 24 111 99
150 PN 16 8 × M 20 99 85
150 PN 40 8 × M 24 136 120
200 PN 10 8 × M 20 141 101
200 PN 16 12 × M 20 94 67
200 PN 25 12 × M 24 138 105
250 PN 10 12 × M 20 110
250 PN 16 12 × M 24 131
250 PN 25 12 × M 27 200
300 PN 10 12 × M 20 125
300 PN 16 12 × M 24 179
300 PN 25 16 × M 27 204
350 PN 10 16 × M 20 188
350 PN 16 16 × M 24 254
350 PN 25 16 × M 30 380
400 PN 10 16 × M 24 260
400 PN 16 16 × M 27 330
400 PN 25 16 × M 33 488
450 PN 10 20 × M 24 235
450 PN 16 20 × M 27 300