Loading...
Electrical connection Proline Promag L 400
28 Endress+Hauser
Remote version
E1
E2
GND
E
S1
E1
E2
S2
GND
E
S
5
7
4
37
42 41
6
5
7
8
4
37 36
n.c. n.c.
21
1
2
n.c.
42 41
A
B
A0020534
 7 Remote version terminal assignment
A Transmitter wall-mount housing
B Sensor connection housing
1 Electrode cable
2 Coil current cable
n.c. Not connected, insulated cable shields
Terminal No. and cable colors: 6/5 = brown; 7/8 = white; 4 = green; 36/37 = yellow
7.1.4 Pin assignment, device plug
PROFIBUS DP
For use in the non-hazardous area and Zone 2/Div. 2.
Device plug for signal transmission (device side)
3
2
4
1
5
A0016811
Pin Assignment Coding Plug/socket
1 B Socket
2 A PROFIBUS DP
3
4 B PROFIBUS DP
5 Grounding/shielding