Proline Promag W 400 Electrical connection
Endress+Hauser 23
0-20 mA/4-20 mA HART connection version with additional outputs and inputs
Signal transmission 0-20 mA/4-20 mA HART with additional outputs and inputs
Order code for
"Output" and "Input"
Terminal numbers
Output 1 Output 2 Output 3 Input
26 (+) 27 (-) 24 (+) 25 (-) 22 (+) 23 (-) 20 (+) 21 (-)
Option H • 4-20 mA HART
(active)
• 0-20 mA
(active)
Pulse/frequency
output
(passive)
Switch output
(passive)
-
Option I • 4-20 mA HART
(active)
• 0-20 mA
(active)
Pulse/frequency/
switch output
(passive)
Pulse/frequency/
switch output
(passive)
Status input
Option J • 4-20 mA HART
(active)
• 0-20 mA
(active)
Permanently assigned
Pulse output adjusted
(passive)
Pulse/frequency/
switch output
(passive)
Status input
PROFIBUS DP connection version
PROFIBUS DP signal transmission
Order code for "Output" and "Input" Terminal numbers
26 (RxD/TxD-P) 27 (RxD/TxD-N)
Option L B A
Order code for "Output":
Option L: PROFIBUS DP, for use in non-hazardous areas and Zone 2/div. 2
Modbus RS485 connection version
Signal transmission Modbus RS485
Order code for "Output" and "Input" Terminal numbers
26 (+) 27 (-)
Option M B A
EtherNet/IP connection version
EtherNet/IP signal transmission
Order code for "Output" Connection via
Option N EtherNet/IP connector