Electrical connection Proline Promag W 400
24 Endress+Hauser
Remote version
E1
E2
GND
E
S1
E1
E2
S2
GND
E
S
5
7
4
37
42 41
6
5
7
8
4
37 36
n.c. n.c.
21
1
2
n.c.
42 41
A
B
A0020534
 5 Remote version terminal assignment
A Transmitter wall-mount housing
B Sensor connection housing
1 Electrode cable
2 Coil current cable
n.c. Not connected, insulated cable shields
Terminal No. and cable colors: 6/5 = brown; 7/8 = white; 4 = green; 36/37 = yellow
7.1.4 Pin assignment, device plug
EtherNet/IP
Device plug for signal transmission (device side)
3
2
4
1
A0016812
Pin Assignment Coding Plug/socket
1 + Tx D Socket
2 + Rx
3 - Tx
4 - Rx