Parameter overview with brief description
Parameter Prerequsite Description Selection / User
entry
Factory setting
Assign channel 1 to 4 The Extended HistoROM
application package is
available.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Assign process variable to
logging channel.
Off
Volume flow
Corrected volume
flow
Corrected methane
volume flow
Mass flow
Energy flow
Methane fraction
Calorific value
Wobbe index
Temperature
Sound velocity
Flow velocity
Acceptance rate
Signal asymmetry
Turbulence
Signal strength
Signal to noise
ratio
Current output 1
Off
Logging interval The Extended HistoROM
application package is
available.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Define the logging interval for
data logging. This value
defines the time interval
between the individual data
points in the memory.
1.0 to 3 600.0 s 10.0 s
Clear logging data The Extended HistoROM
application package is
available.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Clear the entire logging data. Cancel
Clear data
Cancel