Proline Prosonic Flow B 200 HART System integration
Endress+Hauser 53
The assignment of the measured variables to the dynamic variables can be modified and
assigned as desired via local operation and the operating tool using the following
parameters:
Expert → Communication → HART output → Output → Assign PV
Expert → Communication → HART output → Output → Assign SV
Expert → Communication → HART output → Output → Assign TV
Expert → Communication → HART output → Output → Assign QV
The following measured variables can be assigned to the dynamic variables:
Measured variables for PV (primary dynamic variable)
Volume flow
Corrected volume flow
Corrected methane volume flow
Energy flow
Mass flow
Methane fraction
Gross calorific value
Wobbe index
Temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary dynamic
variable)
Volume flow
Corrected volume flow
Corrected methane volume flow
Energy flow
Mass flow
Methane fraction
Gross calorific value
Wobbe index
Temperature
Totalizer 1
Totalizer 2
Totalizer 3
9.3 Other settings
9.3.1 Burst mode functionality in accordance with HART 7
Specification
Navigation
"Expert" menu → Communication → HART output → Burst configuration → Burst
configuration 1 to 3
Burst configuration
Burst configuration 1 to 3
Burst mode 1 to 3
Burst command 1 to 3