Technical data Proline Prosonic Flow B 200 HART
144 Endress+Hauser
16.11 Operability
Local operation Via display module
Order code for "Display; Operation", option C "SD02" Order code for "Display; Operation", option E "SD03"
+
E
1
A0015544
1
+
E
A0015546
1 Operation with pushbuttons 1 Operation with touch control
Display elements
4-line display
With order code for "Display; operation", option E:
White background lighting; switches to red in event of device errors
Format for displaying measured variables and status variables can be individually
configured
Permitted ambient temperature for the display: –20 to +60 °C (–4 to +140 °F)
The readability of the display may be impaired at temperatures outside the temperature
range.
Operating elements
With order code for "Display; operation", option C:
Local operation with 3 push buttons: , ,
E
With order code for "Display; operation", option E:
External operation via touch control; 3 optical keys: , ,
E
Operating elements also accessible in various hazardous areas
Additional functionality
Data backup function
The device configuration can be saved in the display module.
Data comparison function
The device configuration saved in the display module can be compared to the current
device configuration.
Data transfer function
The transmitter configuration can be transmitted to another device using the display
module.