Proline t-mass 65F, 65I
Endress+Hauser 9
Terminal assignment
Electrical connection remote
version
a0005123
A Wallmount housing; Non-hazardous area and zone 2 (ATEX II3G)
B Wallmount housing; Zone 1 (ATEX II2G)
C Remote sensor insertion version
D Remote sensor flanged version
Wire colors (when supplied by Endress+Hauser):
Terminal no. 41 = white; 42 = brown; 43 = green; 44 = yellow
(Color code according to DIN 47100)
Warning!
Do not provide separate power to remote sensor. The power must be provided by the transmitter.
Terminal No. (inputs/outputs)
Order variant 20 (+) / 21 (–) 22 (+) / 23 (–) 24 (+) / 25 (–) 26 (+) / 27 (–)
Fixed communication boards (permanent assignment)
65***-*********A - - Frequency output
Current output
HART
65***-*********B Relay output Relay output Frequency output
Current output
HART
65***-*********J - - +5V (ext. termination) PROFIBUS DP
65***-*********Q - - Status input MODBUS RS485
65***-*********R - - Current output 2
Ex i, active
Current output 1
Ex i active, HART
65***-*********S - -
Frequency output
Ex i, passive
Current output Ex i
Active, HART
65***-*********T - -
Frequency output
Ex i, passive
Current output Ex i
Passive, HART
65***-*********U - - Current output 2
Ex i, passive
Current output 1
Ex i passive, HART
Flexible communication boards
65***-*********5 Status input Current input Frequency output Current output
HART
65***-*********6 Status input Current input Current output 2 Current output
HART
65***-*********8 Status input Frequency output Current output 2 Current output
HART
C D
41 42 43 44
GND
6
10V
COMMS
+
-
+
-
GND
COMMS
--
++
41 42 43 44
6…
10V