Prosonic S FDU90/91/91F/92/93/95/96
22 Endress + Hauser
Ordering information
Product structure FDU90
010 Approval
C IEC Ex t IIIC IP65 Da/Db, Ex ma II T6/T5 Gb (in preparation)
D IEC Ex ma IIC T6 Gb (in preparation)
E ATEX II 1/2 D, ATEX II 2G Ex ma II T6 (in preparation)
G ATEX II 3G Ex nA II T6 (in preparation)
H ATEX II 3D (in preparation)
J ATEX II 2G Ex ma II T6 (in preparation)
Q FM Cl.I,II,III Div. 1+2 Gr.A-G, zone 1,2,21,22 (in preparation)
R Non-hazardous area
S CSA C/US Cl.I,II,III Div.1+2 Gr.A-G, zone 1,2 (in preparation)
U CSA General Purpose (in preparation)
V TIIS Ex is IIC T6 (in preparation)
1 NEPSI DIP (in preparation)
020 Process connection (threaded boss)
G Thread ISO228, PVDF; rear side G1, front side G1-1/2
N Thread ANSI, PVDF; rear side NPT1, front side NPT1-1/2
W Ceiling mounting; front side G1-1/2
030 Cable length
15 m/16 ft
2 10 m/32 ft
3 15 m/49 ft
4 20 m/65 ft
5 25 m/82 ft
6 30 m/98 ft
8 ... m (variable length, up to 300 m)
A ... ft (variable length, up to 985 ft)
035 Heater
AW/o
B Connection to 24 VDC
Note Technical Information FMU90! (Temperature compensation)
040 Additional option
A Basic version
B Flooding protection tube
FDU90 - product designation