EasyManuals Logo

Endress+Hauser Prosonic S Series User Manual

Endress+Hauser Prosonic S Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
Prosonic S FDU90/91/91F/92/93/95/96
6 Endress + Hauser
Operating frequency
Output
Signal transmission analogue voltages
Auxiliary energy
Power supply supplied by the transmitter FMU90
Sensor heater (for FDU91) The FDU90 and FDU91 sensors are available in a version with heater. The power for this heater must be
provided by an external power supply unit. The supply voltage is connected to the brown (BN) and blue (BU)
strands of the sensor cable.
Technical data
24 VDC ±10%; residual ripple < 100 mV
250 mA per sensor
!
Note!
If the sensor heater is applied, the integrated temperature sensor can not be used. Instead, an external
temperature sensor (Pt100 or FMT131 from Endress+Hauser) must be used. The transmitter FMU90 is
available in a version with an input for the external temperature sensor. For details refer to Technical
Information TI397F.
!
Note!
The power for the sensor heater can be supplied by the power supply RNB130 from Endress+Hauser (see
chapter "Accessories").
Sensor Operating frequency
FDU90 90 kHz
FDU91 43 kHz
FDU91F 42 kHz
FDU92 30 kHz
FDU93 27 kHz
FDU95 - *1***
(low temperature version)
17 kHz
FDU95 - *2***
(high temperature version)
18 kHz
FDU96 11 kHz

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Prosonic S Series and is the answer not in the manual?

Endress+Hauser Prosonic S Series Specifications

General IconGeneral
BrandEndress+Hauser
ModelProsonic S Series
CategoryAccessories
LanguageEnglish

Related product manuals