Prosonic S FDU90/91/91F/92/93/95/96
26 Endress + Hauser
Product structure FDU95
010 Approval
C IEC Ex t IIIC IP6x Da/Db, Ex t IIIC IP6x Db
D IEC Ex t IIIC T6 Gb, Ex t IIIC IP6x Da/Db, Ex t IIIC IP6x Db
EATEX II 1/2 D
H ATEX II 3D (in preparation)
J ATEX II 2G Ex ma II T6, ATEX II 1/D
P FM Cl.II Div.1 Gr.E-G, zone 2,21,22
R Non-hazardous area
T CSA Cl.II Div.1 Gr.E-G, zone 2
U CSA General Purpose
W TIIS dust-Ex DP12 (in preparation)
1 NEPSI DIP (in preparation)
015 Temperature; blocking distance; material
1 -40 ... +80°C/176°F; 70 cm/2.3ft; membrane: 316L; PEcoated
2 -40 ... 150°C/302°F; 90 cm/2,9ft; membrane: 316L
020 Process connection (threaded boss)
G Thread ISO228 G1, UP
N Thread ANSI NPT1, UP
030 Cable length
15 m/16 ft
2 10 m/32 ft
3 15 m/49 ft
4 20 m/65 ft
5 25 m/82 ft
6 30 m/98 ft
8 ... m (variable length, up to 300 m)
A ... ft (variable length, up to 985 ft)
040 Additional option
A Basic version
FDU95 - product designation