Prosonic T FMU30
Endress+Hauser 13
Environment
Ambient temperature range 20 °C to +60 °C (4 °F to +140 °F)
Use a protective cover, in order to protect the sensor from direct sun or rain ä 26, "Weather protection
cover".
Storage temperature 40 °C to +80 °C (40 °F to +176 °F)
Resistance to alternating
temperature cycles
To DIN EN 60068-2-14; Nb test : +60°C/20°C (+140 °F/4 °F), 0.5K/min, 100cycles
Climate class DIN EN 60068-2-38 (Test Z/AD) DIN/IEC 68 T2-30Db
Ingress protection With closed housing, tested according to
IP68, 24h at 1.83 m (6.0 ft) under water surface
IP66
With open housing: IP20 (also ingress protection of the display)
Vibration resistance DIN EN 60068-2-64 / IEC 68-2-64: 20 to 2000 Hz, 1 (m/s
)
2
/Hz; 3 x 100 min
Electromagnetic compatibility
(EMC)
Electromagnetic compatibility to EN 61326. For details refer to the declaration of conformity.
With regard to interference immunity the requirements for "industrial environment" are met.
Influence of EMC < 1 % FS
Process
Process temperature range 20°C to +60°C (4 °F to +140 °F)
A temperature sensor is integrated in the sensor for correction of the temperature-dependent time-of-flight.
Process pressure range 0.7 bar to 3 bar abs. (10.15 psi to 43.5 psi)
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru