EasyManua.ls Logo

Endress+Hauser Prosonic T FMU30 - Cantilever with Mounting Frame or Wall Bracket

Endress+Hauser Prosonic T FMU30
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Prosonic T FMU30
24 Endress+Hauser
Cantilever with mounting
frame or wall bracket
A0019566
A Installation with cantilever and wall bracket
B Installation with cantilever and mounting frame
1 Cantilever
2 Mounting frame
3 Wall bracket
Cantilever
A0019349
The 50 mm (2.17 in) or 62 mm (2.44 in) orifices serve for the mounting of the 1½" or 2" sensor, respecitvely.
The 22 mm (0.87 in) orifice may be used for an additional sensor.
Fixing screws are supplied.
3
1
2
AB
1
A B C D Weight Sensor Material Order Code
585 (23) 250 (9.84) 2 (0.08) 200 (7.87) 1.9 kg
(4.19 lbs)
1½" 316Ti (1.4571) 52014132
galv. steel 52014131
2" 316Ti (1.4571) 52014136
galv. steel 52014135
1085 (42.7) 750 (29.5) 3 (0.12) 300 (11.8) 4.4 kg
(9.7 lbs)
1½" 316Ti (1.4571) 52014134
galv. steel 52014133
2" 316Ti (1.4571) 52014138
galv. steel 52014137
mm (in)
A
D
M8
35 (1.4)
50 (2.0)
20 (0.8)
105 (4.1)
50/62
(2.0/2.4)
22 (0.9)
C
C
6.5 (0.3)
15 (0.6)
100 (3.9)
25 (1.0)
35 (1.4)
100 (3.9)75 (2.9)
B
20 (0.8)
75 (2.9)
mm (in)
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru