EasyManua.ls Logo

Endress+Hauser RA33 - Page 62

Endress+Hauser RA33
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix Batch Controller RA33
62 Endress+Hauser
Units 100001-00 Select your unit system.
!
Note!
All units are switched to the factory settings, but config-
ured values are not converted.
Fault switching 100002-00 If the device detects a system error (e.g. hardware defect)
or a fault (e.g. cable open circuit), the selected output
switches.
Option: not used, relay 1/2 or open collector 1/2
Date/time setting Date/time set-up
Date format 110000-00 Select in which format the date is to be set and displayed.
Time format 110001-00 Select in which format the time is to be set and displayed.
Date/time Set date/time
UTC time zone 120000-00 Current UTC time zone on (UTC = coordinated universal
time).
Actual date 120001-00 Actual date. Format as configured under date format.
Actual time 120002-00 Actual time. HH:MM, 12/24-hour as configured in the
time format.
Change
UTC time zone
Date/time
120010-00
120013-00
Change the date and time here.
NT/ST changeover NT/ST changeover
NT/ST changeover 110002-00 Function of the summer (daylight savings) time/standard
time switching. Automatic: switching according to valid
guidelines of the selected region; manual: configure
switching times in the next items; Off: no time switcho-
ver.
NT/ST region 110003-00 Selects the regional settings for summer/normal time
changeover.
Begin summer time
Occurrence 110005-00 Day in spring on which the switch from standard time to
summer time takes place, e.g. for the fourth Sunday in
March: select 4.
Day 110006-00 Day of the week on which the switch from standard time
to summer time takes place in spring, e.g. for the fourth
Sunday in March: select Sunday.
Month 110007-00 Month on which the switch from standard time to sum-
mer time takes place in spring, e.g. for the fourth Sunday
in March: select March.
Date 110008-00 Day, when in the spring a change from normal to summer
time occurs.
Time 110009-00 Time at which the changeover from normal time to sum-
mer time is forwarded by one hour (format: hh:mm).
End summer time
Occurrence 110011-00 Day in autumn on which the switch from summer time to
standard time takes place, e.g. for the fourth Sunday in
October: select 4.
Day 110012-00 Day of the week on which the switch from summer time
to normal time takes place in autumn, e.g. for the fourth
Sunday in October: select Sunday.
Month 110013-00 Month on which the switch from summer time to stan-
dard time takes place in autumn, e.g. for the fourth Sun-
day in October: select October.
Date 110014-00 Day, when in the autumn a change from summer to nor-
mal time occurs.
Time 110015-00 Time at which the changeover from summer time to nor-
mal time is forwarded by one hour (format: hh:mm).

Other manuals for Endress+Hauser RA33

Related product manuals