Soliphant M FTM50, FTM51, FTM52
Endress+Hauser 25
Ordering information
Soliphant M FTM50
10 Approval
A Non-hazardous area
C CSA General Purpose, CSA C US
D FM DIP Cl. II, III, Div. 1+2 Group E-G +
CSA DIP Cl. II, III, Div. 1+2 Group G+coal dust
E FM DIP + CSA DIP Cl. II, III, Div. 1+2 Group E-G
F FM IS Cl. I, II, III, Div. 1+2 Group A-G +
CSA IS Cl. I, II, III, Div. 1+2 Group A-D, G+coal dust
G FM IS + CSA IS Cl. I, II, III, Div.1+2 Group A-G
H FM XP Cl. I, II, III, Div. 1+2 Group A-G +
CSA XP Cl. I, II, III, Div. 1+2 Group A-D, G+coal dust
J FM XP + CSA XP Cl. I, II, III, Div. 1+2 Group A-G
YSpecial version
1 ATEX II 1 D, II 1/2 GD, II 1/3 GD EEx ia IIC T6
2 ATEX II 1/2 D
3 ATEX II 3 D, II 3 G EEx nA/nL/nC
4 ATEX II 1/3 D
5 ATEX II 1 D, II 1/2 G EEx de (ia) IIC T6
6 ATEX II 1 D, II 2 G EEx d (ia) IIC T6
7 ATEX II 1 D, ATEX II 1 G EEx ia IIC T6, XA -> Observe safety instructions!
20 Process connection
AF 2", 150 LBS, RF, flange ANSI B16.5
AG 3", 150 LBS, RF, flange ANSI B16.5
AH 4", 150 LBS, RF, flange ANSI B16.5
B3 DN50, PN25/40 A, flange EN1092-1 (DIN2527 B)
BS DN80, PN10/16 A, flange EN1092-1 (DIN2527 B)
BT DN100, PN10/16 A, flange EN1092-1 (DIN2527 B)
GG Thread DIN2999 R1½
GJ Thread ANSI NPT1½, d = 1.67" sensor
GK Thread ANSI NPT1¼, d = 1.38" sensor
GX Thread ANSI NPT1½, d = 1.38" sensor -> Suitable for ISA nozzles
KF 10K 50, RF, flange JIS B2238
KG 10K 80, RF, flange JIS B2238
KH 10K 100, RF, flange JIS B2238
TD Tri-Clamp ISO2852, DN40-51 (2")
YY Special version
30 Material
2 316L
9Special version
40 Fork; bulk density
A 155 mm/6 inch; min. 10 g/l
K 100 mm/4 inch; min. 50 g/l
YSpecial version
50 Electronics; output
1 FEM51: 2-wire 19...253 V AC, Probe circuit, intrinsically safe
2 FEM52: 3-wire PNP 10...55 V DC, Probe circuit, intrinsically safe
4 FEM54: relay DPDT 19...253 V AC/55 V DC, Probe circuit, intrinsically safe
5 FEM55: 8/16 mA 11...36 V DC
7 FEM57: 2-wire PFM
8 FEM58: NAMUR + push button (H-L signal)
9Special version
60 Type of probe
A Compact
D 6 m cable > separate housing
E 20 ft cable > separate housing
G 6 m cable, reinforced > separate housing
H 20 ft cable, reinforced > separate housing
YSpecial version

Table of Contents

Other manuals for Endress+Hauser Soliphant M FTM51

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Soliphant M FTM51 and is the answer not in the manual?

Endress+Hauser Soliphant M FTM51 Specifications

General IconGeneral
BrandEndress+Hauser
ModelSoliphant M FTM51
CategorySwitch
LanguageEnglish

Related product manuals