Environment
Ambient temperature range -50...+70 °C (-40...+70 °C with F16 housing)
Storage temperature -50...+85 °C
Climate class Climatic protection as per DIN IEC 68 Part 2-38, Fig. 2a
Degree of protection IP66/IP67 (housing F15, F16, F17), NEMA4X
IP66/IP68 (housing F13, T13), NEMA4X, NEMA6P
Vibration resistance DIN 60068-2-27 / IEC 68-2-27: shock 30 g; vibration 0.01 g
2
/Hz
Electrical safety IEC 61010, CSA 1010.1-92, FM3600
Electromagnetic compatibility Interference emission to EN 61326, Electrical equipment Class B,
Interference immunity to EN 61326, Annex A (Industrial)
Process
Medium temperature limits Permitted ambient temperature T
a
at housing depending on the process temperature T
p
in the container:
L00-FTM5xxxx-05-05-xx-xx-001
x °C = (1.8 x + 32) °F
* Restriction on –40 °C with F16 housing
Thermal shock resistance Maximum 120 K
Limiting medium pressure
range
-1...25 bar
Maximum Working Pressure (MWP)
FTM50/51: 25 bar
FTM52: 2 bar (6 bar for EEx d and EEx de)
Burst pressure
FTM50/51: 100 bar
State of aggregation Solids
Grain size 10 mm
40 °C
80 °C
FTM52
FTM50, FTM51
70 °C
T
a
T
a
50 °C
0 °C
50 °C
0 °C50°C 100 °C 150 °C
T
p
T
p
90 °C
50 °C
F16
*
20 °C
20 °C
40 °C

Table of Contents

Other manuals for Endress+Hauser Soliphant M FTM51

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Soliphant M FTM51 and is the answer not in the manual?

Endress+Hauser Soliphant M FTM51 Specifications

General IconGeneral
BrandEndress+Hauser
ModelSoliphant M FTM51
CategorySwitch
LanguageEnglish

Related product manuals