3.g.9 CCS 3000 Version (P5.9)
Shows the software version of CCS 3000
3.g.10 Bootloader Version (P5.10)
Shows the bootloader software version of CCS 3000
3.g.11 Factory Calibration (P5.11)
This parameter is about the calibration of the 4-20mA Pressure Sensor. For factory use only (ENKO Electronic Control
Systems Ltd.).
3.g.12 Temperature Sensor Type (P5.12)
This parameter determines the type of the temperature sensor to be connected to CCS 3000. The 2 types supported are NTC
and KTY.
!Note: A wrong setting of this parameter may cause damage to the compressor due to wrong temperature measurement.
3.g.13 Screw Pressure Active (P5.13)
This parameter activates the pressure sensor (screw pressure) connected to the AN2 input of the CCS 3000.
3.g.14 Screw Pressure Value (P5.14)
The pressure value on the label of the screw pressure sensor (AN2) is to be entered in this parameter.
3.g.15 IN5 Function (P5.15)
Determines the function of the IN5 digital input. The options are;
• Fan Thermic
• Remote Load
• Screw Pressure Switch
• Line Pressure Switch
This input may work in parallel with the parameters P5.13 and P4.5.1 depending on which function is assigned. When IN5
function is set to Remote Load, P4.5.1 will be set to “Remote”. In this case if P4.5.1 is set to anything else than “Remote,
IN5 function will be changed to “Fan Thermic”. If IN5 function is set to any function other than Remote Load, P4.5.1 will
be changed to “Sensor”. The conditions apply for P5.13 Screw Pressure Active parameter.