IQ System Controller 3/3G Quick Install Guide
Plan a location for the
IQ System Controller
Mounting the product
Section A
IQ System Controller is NEMA type 3R rated and can be mounted both indoors
and outdoors. Install the unit where it is not exposed to direct rainfall.
Install this product where cables from PV/IQ Combiner, grid, and IQ Battery
are easily accessible and can be terminated at the IQ System Controller.
This product is designed to be installed on a vertical wall only. Do not install
this product at on the ground.
The mounting surface must be able to support 87 lbs.
Follow all local standards and regulations during installation.
The product operates within an ambient temperature range from -40°C to 50°C.
Do not install this product in a place where it is directly exposed to sunlight.
Do not install the product in a very dusty environment.
This product must not be installed at altitudes above 8,200 ft (2,500 m).
In ood-prone areas, ensure that the clearance from the ground is sucient to
avoid water ingress.