IQ7+ and I Q7A Installation and Operation Manual - India
30 © 2023 Enphase Energy Inc. All rights reserved. August 2023
USM-00002-1.0
IQ7A-72-2-INT Microinverter parameters
Overvoltage class AC port
Number of input DC connectors (pairs)
1
AC connector type IQ Cabling (refer to separate datasheet for cable and
DC connector type
Staubli MC4 (using Q-DCC-2 adapter)
Dimensions (HxWxD)
212 mm (8.3″) x 175 mm (6.9″) x 30.2 mm (1.2″) (without
mounting brackets)
Weight (with mounting plate)
1.08 kg (2.38 lbs)
Natural convection – no fans
Enclosure Class II double-insulated, corrosion-resistant polymeric
IP Rating
Outdoor - IP67
Maximum altitude
2,600 metres
Grid compliance
IEC 62109-1, IEC-62109-2/IS 16221; IEC 61727
EN IEC 62109-1, EN IEC 62109-2
EMC EN IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-3, EN IEC
50065-1, 50065-2-1
Advanced grid functions
2
Power export limiting (PEL), phase imbalance management
(PIM), loss of phase detection (LOP), power factor control Q
Microinverter communication
Power line communication (PLC) 110−120 kHz (Class B), narrow
1. No enforced DC/AC ratio and maximum input power. Modules can be paired if the maximum input voltage is not exceeded and the
maximum input current of the inverter at the lowest and highest temperatures is respected. See the compatibility calculator at module
compatibility.
2. Some of these functions require IQ Gateway Metered with current transformers and/or IQ Relay installed.
*** The maximum input power values are recommended to address region-specific requirements.
IQ Cable specifications
Specification Q-12 single-phase cable
Voltage rating
600 V
Voltage withstand test (kV/1min)