Enterasys G-Series Hardware Installation Guide 1-5
Forfangroup1,whenallappropriatetemperaturesensorsregistertemperaturesof50degreesC
orlower,group1fansrunat60%ofmaximumspeed.Iffirmwaredetectsanysensorreading(on
thebaseboardoranyIOM)above50degreesC,allgroup1fanswillincreaseto100%of
maximum
speed.Inaddition,iffirmwaredetectsafailureofanyfaningroup1,allothergroup1fanswillbe
increasedto100%ofmaximumspeed.
Forfangroup2,behaviorissimilar.Whenallappropriatetemperaturesensorsregister
temperaturesof50degreesCorlower,group1fans
runat60%ofmaximumspeed.Iffirmware
detectsanysensorreading(ontherearofthebaseboardoranypowersupplysensor)above50
degreesC,allgroup2and3fanswillincreaseto100%ofmaximumspeed.Inaddition,iffirmwa re
detectsafailureofanyfan
ingroup2or3,allothergroup2and3fanswillbeincreasedto100%of
maximumspeed.
RefertotheEnterasysGSeriesCLIReferenceforinformationonusingtheG3CLItodeterminefan
status.