EasyManua.ls Logo

Enterasys G3G124-24 - Connecting to AC Power Receptacles

Enterasys G3G124-24
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting to the Console Port
2-14 Installation
2. Plugtheotherendofeachpowercordintoanappropriate,dedicatedgroundedACoutletas
follows.
•G3PWRPOErequiresa20Ampcircuit.
•G3PWRrequiresa15Ampcircuit.
3. VerifythattheappropriatepowerLEDs(PWR1andPWR2,notshown),locatedonthefront
panel,turnonas
describedinPowerLEDDisplaysonpage 214andtheSYSTEMLED
turnsreduntiltheGSeriescompletesitsinitialization.
Iftheinitializat ionprocessissuccessful,theSYSTEMLEDturnsgreen.IftheSYSTEMLEDdoes
notturngreen,refertoChapter 3fortroubleshootinginformation.
Power LED Displays
Onceoneormorepowersuppliesareinstalledandpowerisconnectedtotheswitch,thepower
LEDs(PWR1andPWR2)willindicatetheswitch’spowermode(redundantoradditive)as
follows:
RefertoSupportedPowerConfigurationsonpage 26forpossibleconfigurationsineachpower
mode.
Refertothe
EnterasysGSeriesCLIReferenceforinformationonhowtospecifywhethertwo
installedpowersupplieswilloperateinadditiveorredundantmode.
Connecting to the Console Port
Connecting to the RJ45 Console Port
TheRS232consoleportusesastandard8pinRJ45connector.AnRJ45toDB9adapterisprovided
withtheswitch,butyoumustprovideyourownRJ45toRJ45straightthroughconsolecable.
RefertoTable 22onpage 215forconsoleportpinoutassignments.
RefertoTable 23
onpage 215forRJ45toDB9adapterpinoutassignments.
Note: To take full advantage of the load sharing and redundancy capabilities, each power cord
should be plugged into a separate dedicated AC outlet.
Display Status
Off Power supply not present.
Green Normal operation.
Amber Not enough power for redundancy. Operating in additive power mode.
Red Power failure.
Note: Only one console port on the G-Series switch can be active at any given time, either the RJ45
or the USB port.

Table of Contents

Other manuals for Enterasys G3G124-24

Related product manuals