EasyManua.ls Logo

Enterasys G3G124-24 - PoE (Power over Ethernet) Support; Fan Management

Enterasys G3G124-24
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Features
1-4 Introduction
PoE (Power over Ethernet) Support
TheG3G12424Pswitchis802.3afcompliantoutofbox.TheG3G12424andtheG3G24TXIOM
canbeequippedwithuserinstalledoptionalPoEmodulestomakethem802.3afcompliant.For
moreinformationaboutinstallingoptionalPoEmodules,seeInstallinganOptionalPoEModule
ontheG3G24TX
IOMonpage 210andInstallinganOptionalPoEModuleintheG3G12424
Switchonpage 223.
TheG3GswitchesandIOMsthatare802.3afcompliantprovidePoweroverEthernetcable
connectionsfromtheirRJ45frontpanelconnectorstopowereddevices(PDs)inthenetwork.
PoweroverEthernet(PoE)
referstotheabilitytoprovide48Vdcpowertoapowereddeviceusing
thesameEthernetcablingthatprovidesdata.ModernEthernetimplementationsemploy
differentialsignalsovertwistedpaircables.Thisrequiresaminimumoftwotwistedpairsfora
singlephysicallink.Bothendsofthecableare
isolatedwithtransformersblockinganyDCor
commonmodevoltageonthesignalpair.PoEexploitsthisfactbyusingtwotwistedpairsasthe
twoconductorstosupply adirectcurrent.Onepaircarriesthepowersupplycurrentandtheother
pairprovidesapathforthereturncurrent.While
severalproprietarylegacyimplementationsof
PoEhavebeendeployedbyLANequipmentvendors,in2003theIEEEpublishedtheIEEE802.3af
specification,whichispartofthe802.3suiteofstandards.
TheswitchisfullycompliantwiththeIEEE802.3afstandard.Itsupportsthestandardresistor‐
baseddetectionmethod,aswell
asACdisconnectcapability.Theswitchisalsocapableof
supplying15.4wattsofpowerto96portsinnonredundantpowermode,and9.4wattsofpowerto
96portsinredundantpowermode.
Powered Device Classifications (PDs)
PDsaredevicesthatreceivetheiroperating48VdcpowerthroughaneworexistingEthernet
cablefromaswitchorotherdevicethatcanprovideaPoEcompliantportconnection.This
enablesthePDtooperateinalocationwithoutlocalpower.Forexample:
DevicessuchasPoEcompliantremote
EXITsignsandPersonalDataAssistants(PDAs),
DevicesthatsupportVoiceoverIPsuchasPoEcompliantdigitaltelephones,
DevicesthatsupportWirelessApplicationProtocol(WAP)suchassecuritycameras,laptop
PCs,andmanymoredevices.
Fan Management
TheG3systemsupportsthreegroupsofindependentlycontrollablefansandseveralfirmware
readablethermalsensors.Fanzonesareasfollows:
•Group1(fans1,2,and3)islocatedinthefrontleftoftheswitchtocooltheEthernet
subsystemandoptionalIOMmoduleslots.
•Group2(fans8and
9)islocatedinthebackleftoftheswitchbehindGroup1tocooltheCPU
subsystem.
•Group3(fans4,5,6,and7)islocatedoneithersideofthepowerslotstocoolthepower
supplies
FanspeedsaredeterminedbythermalsensorslocatedthroughouttheG3
system.Thefirmware
samplestheappropriatethermalsensorsatregularintervals,andsetstheappropriatefanspeeds.
Fangroup1drivesairflowacrossthefrontportionofthechassis,andfangroups2and3driveair
flowacrosstherearportionofthechassis.

Table of Contents

Other manuals for Enterasys G3G124-24

Related product manuals