Questions and Answers

  • S
    Sean LopezSep 12, 2025
    What should I do if my Enthermics DC150 Food Warmer displays 'More heater pads detected than set for'?
    • G
      garciakevinSep 12, 2025
      If your Enthermics Food Warmer displays 'More heater pads detected than set for', hold the On/Off button for 12 seconds until the display shows "PAd#” (# = number of pads selected [3-7]). Then, press the up or down arrow to adjust to the correct number of pads.
  • A
    Anthony TaylorSep 10, 2025
    What to do if the sensor reading is above the maximum allowable temperature set-point and over temp value in my Enthermics DC150?
    • T
      Tiffany Henderson MDSep 10, 2025
      If the sensor reading on your Enthermics Food Warmer is above the maximum allowable temperature set-point and over temp value, contact service.
  • K
    Kyle JohnsonSep 9, 2025
    What should I do if the temperature of the cavity sensors 1 and 2 differ by more than 1.7ºC (3ºF) in my Enthermics DC150?
    • M
      Melissa HarrisSep 9, 2025
      If the temperature of the cavity sensors 1 and 2 in your Enthermics Food Warmer differ by more than 1.7ºC (3ºF), remove the product and allow the appliance to cool down. Verify that the product sensor is clean and operating correctly. Press the power button to clear the error code. If the error persists, contact service to replace the sensor switch assembly.
  • T
    Todd PonceSep 8, 2025
    What does it mean if my Enthermics DC150 Food Warmer displays 'Sensor is open' and how do I fix it?
    • J
      Jeremy ParkerSep 8, 2025
      If your Enthermics Food Warmer displays a 'Sensor is open' error, acknowledge it by pressing the on/off button and detach the sensor from the appliance. Use an Ohm meter to measure the resistance of the sensor at 25°C (77°F). If the reading is 10 KOhm ±1.5 KOhm, replace the display. If the reading is ±2 KOhm, replace the sensor. Check the wires for integrity and ensure proper and secure connections at the control and terminal block, re-securing any faulty connections if necessary. If the error persists, contact service.
  • T
    troy85Aug 23, 2025
    What to do if my Enthermics Warming Drawer displays error E-10?
    • S
      Scott ThomasAug 23, 2025
      If the Enthermics Warming Drawer displays error code E-10, ES10, ES20, ES30, ES40, ES50, ES60, or ES70, it indicates a shorted sensor. First, acknowledge the error by pressing the ON/OFF button. If the error persists, a qualified technician should test the sensor. This involves detaching the sensor, using an Ohm meter to measure its resistance at 0°C (32°F) in ice water. A reading of 32.6 KOhm ±1.5 KOhm suggests replacing the display, while a reading of ±2 KOhm indicates replacing the sensor. Also, check the wires and connections for integrity and security. If problems persist, contact service.
  • T
    Tony ThomasSep 6, 2025
    What to do if my Enthermics Food Warmer heating pad has not reached the set-point temperature?
    • E
      ebriggsSep 6, 2025
      If the heating pad in your Enthermics Food Warmer hasn't reached the set-point temperature, first acknowledge the error by pressing the on/off button. Then, turn the appliance off, unplug it from AC power, and use an Ohm meter to measure resistance between the L:(Line) & N:(Neutral) leads of a cold heater pad. If the error persists, contact service.
  • F
    Franklin StoneSep 5, 2025
    What to do if the Enthermics Food Warmer heater pad has an over-temp error?
    • R
      robertbarajasSep 5, 2025
      If your Enthermics Food Warmer displays a heater pad over-temp error, acknowledge the error by pressing the on/off button. Then, allow the appliance to cool down. If the error persists, contact service.
  • R
    Ronald WrightSep 4, 2025
    What does error E-31 mean on my Enthermics Warming Drawer?
    • H
      Heather CarsonSep 4, 2025
      If your Enthermics Warming Drawer displays error E-31, it indicates that the sensor reading is above the maximum allowable temperature set-point. Contact service.
  • S
    Sherry VincentSep 2, 2025
    What does error E-95 mean on my Enthermics Warming Drawer?
    • J
      Jamie CarrilloSep 3, 2025
      If your Enthermics Warming Drawer displays error code E-95, it indicates a Factory Test pin short was detected. Make sure no debris is causing a short between the test pins. If the pins are fine, replace the control.
  • J
    jwilliamsSep 1, 2025
    How to resolve error code E-70 on my Enthermics Warming Drawer?
    • T
      Thomas ThompsonSep 2, 2025
      If your Enthermics Warming Drawer displays error code E-70, it means more heater pads are detected than set for. Hold the ON/OFF button for 12 seconds until the display shows "PAd#" (# = number of pads selected [3-7]). Use the UP or DOWN arrow to adjust to the correct number of pads.

Summary

Safety

Safety Precautions

Details electrical, usage, and operator training precautions to prevent injury and equipment damage.

Operator Qualifications and Servicing

Outlines operator qualifications, warmer condition requirements, and servicing guidelines for safe use.

Specifications

Installation

How to Unpack the Warmer

Step-by-step guide on safely removing the warmer from its packaging and inspecting for damage.

How to Install the Warmer

Instructions for correctly positioning and connecting the warmer to electrical power for operation.

Operation

Turn Warmer On and Off

Step-by-step instructions for powering the warmer on and off using the control panel buttons.

Operate the Blanket Warmer

Instructions on setting temperature, loading, and monitoring the warming process for blankets.

Maintenance

Maintenance Schedule

Outlines daily, monthly, and yearly checks and cleaning tasks for optimal performance and longevity.

How to Clean the Warmer

Detailed instructions for safely cleaning the warmer's exterior, interior, and specific components.

Troubleshooting

Error Codes

A comprehensive list of error codes, their causes, and required actions for diagnosis and repair.

Electrical Information

Warranty

Enthermics DC150 Specifications

General IconGeneral
BrandEnthermics
ModelDC150
CategoryFood Warmer
LanguageEnglish

Related product manuals