Partial Hold Open Time (00÷60s)
Hold open time for Inner & Outer impulses with operation
mode selection PARTIAL and for the Nurse impulse.
Push & Go Hold Open Time (00÷60s)
Hold open time after a Push&Go.
Auto Width Activation Time (00÷60s)
Auto width activation time is available if parameter 61=01
"Auto Width" is selected. If the door has not closed during the
auto width activation time and the door is open or opening
the door will open to full open door.
Auto Width Resume Time (00÷60s)
When the door have been closed during the auto width
resume time, the next opening impulse will open the
door to partial open position. Only available if parameter
"AutoWidth" 61=01
Jam Hold Time (00÷10s)
Sets how long time the door shall be stopped when a jam
is detected during opening and also the time until the door
can restart after a Stop impulse.
Interlock Disable Time (00÷60s)
FUTURE USE
Presence Hold Open Time (00÷60s)
Hold open time for Presence impulses 1&2.
Side Presence Input 1 Configuration (00÷01)
00= N.O.
01= N.C.
Side Presence Input 2 Configuration (00÷01)
00= N.O.
01= N.C.
Side Presence Impulse monitoring (00÷02)
Side presence impulse monitoring is a demand to be acti-
vated according to EN16005 or DIN18650
00= No monitoring of Side Precense impulse. Set to “00” if no
monitoring of Side Presence impulse sensors is required
or if no Side Presence impulse sensors are installed.
01= Side Presence impulse 1. Set to “01” if one Side
Presence impulse sensor shall be monitored (if only
one sensor, it has to be connected to terminal 2, Side
Presence impulse 1).
02= Side Presence impulse 1 and 2. Set to “02” if two Side
Presence impulse sensors shall be monitored.
TO BE SET
Side Presence Function (00÷01)
00= Safe Speed. If a Side Presence Impulse is activated
during opening, the door shall continue to open with a
safe speed (0,1 m/s).
01= Stop Door. If a Side Presence Impulse is activated during
opening, the door shall stop and be stopped during the
set Presence Hold Open Time (see parameter 26).