29
IP2045EN - 2014-09-22
4.1 Self-controlled safety edge SOFA1-SOFA2 or GOPAVRS
Command Function Description
GOPAV
SOFA1-SOFA2
SAFETY TEST Place the SOFA1-SOFA2 or GOPAVRS device into its hou-
sing for plug-in cards AUX.
Connecting terminal 41 enables a safety edge test cycle
before every operation.
If the test fails the SA led flashes and the test is repeated.
1 6
N.C. STOP SAFETY
DEVICE
Connect the output contact of device SOFA1-SOFA2 to
terminals 1-6 on the control panel (in series with the
photocell output contact, if installed).
1 8
N.C. REVERSAL
SAFETY
DEVICE
Connect the output contact of device SOFA1-SOFA2 to
terminals 1-8 on the control panel (in series with the
photocell output contact, if installed).
ATTENTION: for quick operation on the safety edge, con-
nect it to contact 1-6.