HP SERIES FAN COILS
Supersedes ET115.24-NOM1 (615)
Form ET115.24-NOM1 (519)
INTRODUCTION
E
NVIRO-TEC fan coils represent a prudent
investment which can, with proper installation,
operation, and regular maintenance, give trouble-
free operation and long service.
Your equipment is initially protected under
the manufacturer’s standard warranty;
however, this warranty is provided under the
condition that the steps outlined in this manual for
initial inspection, proper installation, regular
periodic maintenance, and everyday operation of the
equipment be followed in detail.
HP SERIES
(HPP Plenum Return Shown)
This manual s
hould be fully reviewed in advance
of any actual work being done on the equipment.
Should any questions arise, please contact your
local Sales Representative or the factory BEFORE
proceeding.
The equipment covered by this manual is available with
a vast variety of options and accessories. Consult
the approved unit submittal, order acknowledgement,
and other manuals for details on the options and
accessories provided with the equipment on each
project.
INSTALLATION, OPERATION & MAINTENANCE

Questions and Answers

  • D
    Dylan YoungAug 11, 2025
    What to do if my Enviro HP Air Conditioner motor fails to start?
    • R
      Ronnie PatrickAug 11, 2025
      If your Enviro Air Conditioner motor isn't starting, there could be several reasons. The CFM adjustment voltage may be too high (above 10.0 VDC) or too low (below 5.0 VDC). Adjust the CFM voltage accordingly. For units shipped before April 2011, ensure the voltage is between 5.1 VDC and 9.9 VDC. Also, check that the ECM cables are properly connected to the motor by unplugging and reinstalling them. If the ECM cables are damaged, replace them. A mechanical failure could also be the cause, so check if the motor rotates freely. In case of electrical failure, consider replacing the motor. Lastly, oxidized or sulfidized fan relay contacts can prevent the motor from starting, so replace the fan relay if necessary.
  • N
    Nicole MaysAug 19, 2025
    Why does my Enviro Air Conditioner motor surge?
    • N
      nbaileyAug 19, 2025
      If your Enviro Air Conditioner motor is surging, it could be due to a couple of reasons. The fan CFM adjustment voltage might be outside the range of the Fan Calibration Curve; in this case, adjust the voltage to a value within the curve's range. Another possibility is that the external static pressure (ESP) is too high. Check for any obstructions in the discharge and ensure the coil fins are clean. Make sure the plenum opening is unobstructed and that the filter, if present, isn't dirty and doesn't restrict airflow.
  • D
    Dennis James DDSAug 27, 2025
    What to do if my Enviro HP Air Conditioner motor runs in reverse or doesn’t respond to speed adjustment?
    • J
      jaredrodriguezAug 27, 2025
      If the motor in your Enviro Air Conditioner runs in reverse or doesn’t respond to speed adjustments, it indicates a motor failure, and you should replace it.
  • K
    kimberlynewmanSep 2, 2025
    How to fix excessive motor noise in my Enviro Air Conditioner?
    • T
      Tina GarciaSep 2, 2025
      Excessive noise from your Enviro Air Conditioner motor can stem from a few issues. Start by tightening the motor mounting bolts, as they may be loose. If the fan wheel is rubbing against the fan housing, align the wheel within the housing. Also, check if the fan wheel is loose, and if so, align and tighten it.