Presents the manual for the Explosion Protection System and its intended audience.
Covers warranty, limitation of liability, copyright, disclaimer, and quality notices.
Defines terms and symbols used throughout the manual for clarity.
Provides a general overview of the EPACO modular detection and control system.
Lists and describes the main components of the EPACO system.
Detailed description of the EPC, its features, and functions.
Information on the Power Supply Unit (PSU) and its role in powering the system.
Details the Annunciator Module (AM) and Relay Card Module (RC8) for diagnostics and control.
Discusses system response time and component placement for effectiveness.
Details electrical power requirements, circuit breaker specifications, and cabling for the PSU.
Explains system configuration via DIP switches or PC software for EPC, AM, and RC8.
Guides on using DIP switches for EPC configuration and safety features.
Diagram showing the five input contacts and their connections on the EPC.
Diagram showing the three output connections on the EPC.
Diagram illustrating the bus communication connection points on the EPC.
Details on the 4-20mA pressure detector circuits and wiring recommendations.
Information on the contact closure input for various devices and programming options.
Explains the supervisory input for trouble notification and its wiring.
Details the remote disable input circuit for system control and wiring.
Information on the series firing circuit for activating up to six actuators.
Details the fail-safe trouble relay for system fault annunciation.
Explains the fail-safe alarm relay for system alarm annunciation.
Describes the fire bus circuit for sending activation signals between EPCs.
Details the status bus for control information between system modules.
Specifications for the power input requirements of the EPC.
Overview of the EPC's operational states: Normal, Trouble, and Alarm.
Describes the three methods for disarming the EPC system.
Information on retrieving and understanding the EPC's event history records.
Details how the EPC responds to single detector and cross-zone detection alarms.
Explains the purpose of the Status Bus, Fire Bus, and Remote Bus.
General requirements for routine system inspections and maintenance.
Step-by-step procedure for inspecting the control panel and system components.
Details the information and equipment needed for inspections by Fike personnel.
Recommendations for replacing system batteries and actuators at specified intervals.
A mandatory checklist for decommissioning the Explosion Protection System by a qualified engineer.
A list of part numbers and descriptions for spare parts related to the EPC.
A table detailing the meaning of LED indicators and buzzer sounds for system diagnostics.
Comprehensive technical specifications for the Explosion Protection Controller.
Procedure for obtaining authorization before returning components for repair or replacement.