EasyManuals Logo
Home>Epever>Controller>MPPT

Epever MPPT User Manual

Epever MPPT
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
21
24VDC
100W
4.17A
1.5mm
2
/15AWG
Load 2
Output
voltage
Output power
Max. output
current
Recommended wire
12VDC
36W
3A
1mm
2
/16AWG
24VDC
36W
1.5A
0.5mm
2
/20AWG
3.4 Mounting
WARNING: Risk of explosion! Never install the controller in a sealed enclose
with flooded batteries! Do not install the controller in a confined area where
battery gas can accumulate.
WARNING: Risk of electric shock! When wiring the solar modules, the PV
array can produce a high open-circuit voltage, so turn off the breaker before
wiring and be careful when wiring.
CAUTION: The controller requires at least 150mm of clearance above and
below for proper airflow. Ventilation is highly recommended if mounted in an
enclosure.
Installation Procedure:
Step 1: Determine the installation location and heat-dissipation space
The controller requires at least 150mm of clearance above and below for proper
airflow, shows as below figure.