2
Read this manual carefully and master related safety cautions.
3. Professional and technical personnel is allowed to do
Install the controller to a specified location;
Conduct trial operations for the controller;
Operate and maintain the controller
4. Safety cautions before installation
IMPORTANT: When you receive the controller, check whether there is any
damage that occurred in transportation. Contact the transportation company or
our company in time for any problem.
CAUTION: When storing or moving the controller, follow the instructions in the
manual.
CAUTION: When installing the controller, must evaluate whether the
operation area exists any arc danger.
WARNING: Keep the controller out of reach of children.
5. Safety cautions for mechanical installation
WARNING: Before installation, make sure the controller has no electrical
connection.
WARNING: Ensure enough heat dissipation space for the controller before
installation. Do not install the controller in a harsh environment such as
humid, greasy, flammable, explosive, or dust accumulation.
6. Safety cautions for electrical connection
CAUTION: Check whether all the wiring connections are tight to avoid the
danger of heat accumulation due to loose connections.
WARNING: The input of PV array is a high voltage, do not touch the wiring
connection to avoid electric shock.
7. Safety cautions for controller operation:
WARNING HOT SURFACE: When the controller is running, the heat sink will
generate a lot of heat, and the temperature would be very high, please do
not touch it.

Other manuals for Epever MPPT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epever MPPT and is the answer not in the manual?

Epever MPPT Specifications

General IconGeneral
DisplayLCD
TypeSolar Charge Controller
Nominal System Voltage12V/24V Auto (depending on the model)
Max Charging Current10A to 40A (depending on the model e.g., 10A for Tracer1210AN)
CommunicationRS485
Rated Battery Voltage12V/24V Auto
Protection FeaturesOver Voltage, Reverse Polarity, Over Discharge, Over Heating, Over Load
EfficiencyUp to 98%
DimensionsVaries with model.
ModelTracer AN series (e.g., Tracer1210AN, Tracer2210AN, Tracer3210AN, Tracer4210AN, Tracer1215AN, Tracer2215AN, Tracer3215AN, Tracer4215AN)