27
Low voltage disconnect voltage
11.1V
9.3V
9~17V
Discharging limit voltage
10.6V
9.3V
9~17V
The following rules must be observed when modifying the parameter values in
User for a lithium battery.
A. Over Voltage Disconnect Voltage>Over Charging Protection Voltage(Protection
Circuit Modules(BMS))+0.2V;
B. Over Voltage Disconnect Voltage>Over Voltage Reconnect VoltageCharging Limit
Voltage Equalize Charging VoltageBoost Charging Voltage Float Charging
Voltage>Boost Reconnect Charging Voltage;
C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage Discharging
Limit Voltage.
D. Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage≥
Discharging Limit Voltage;
E. Boost Reconnect Charging voltage> Low Voltage Reconnect Voltage;
F. Low Voltage Disconnect Voltage ≥ Over Discharging Protection Voltage (BMS)+0.2V
The voltage parameters of a lithium battery can be set according to the lithium
battery BMS's voltage parameters.
The required accuracy of BMS shall be no higher than 0.2V. We will not
assume any responsibility for the system abnormal when the accuracy of BMS
is higher than 0.2 v.