EasyManua.ls Logo

Epever UP2000-HM6021 - Page 33

Epever UP2000-HM6021
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
C-2
PV
Utility
Input: Solar only
Output: Utility Priority
C-3
PV
Utility
Input: Solar Priority
Output: Inverter Priority
When the battery voltage goes lower than or equal to AON and has not
been charged to AOF, the below interfaces show different conditions.
When P
PV
MCC* V
BAT
, the utility supplies
the load alone and charges the battery
together with the PV.
When P
PV
> MCC* V
BAT
, PV charges the
battery alone and supplies the load together
with the utility.
C-4
PV
Utility
Input: Solar Priority
Output: Utility Priority
Utility supplies the load, and PV charges
the battery.
When P
PV
P
Load
, PV stops charging
the battery. Instead, it supplies the load
together with the battery.
PV charges the battery, and the utility
supplies the load.
When P
PV
> P
Load
, PV charges the
battery and supplies extra power to the
load.

Related product manuals