33
D-2
PV
Utility
Input: Solar only
Output: Utility Priority
Utility supplies the load.
D-3
PV
Utility
Input: Solar Priority
Output: Inverter Priority
The battery supplies the load alone.
When V
Battery
V
AON
, Simultaneously, it has
not been charged to AOF. Instead, the utility
supplies the load and charges the battery.
D-4
PV
Utility
Input: Solar Priority
Output: Utility Priority
The utility supplies the load alone.
When V
Battery
V
AON
, Simultaneously, it
has not been charged to AOF. Instead, the
utility supplies the load and charges the
battery.
D-5
PV
Utility
Input: Utility & Solar
Output: Un-programmable
Utility supplies the load and charges the
battery.