Epson Artisan 810/835/837/710/725/730/Epson Stylus Photo PX810FW/TX810FW/PX820FWD/TX820FWD/PX830FWD/PX710W/TX710W/PX720WD/TX720WD/PX730WD/TX730WD
Revision G
DISASSEMBLY/ASSEMBLY Disassembly Procedures 146
Confidential
Make sure to insert the decompression tube into the socket on
the Cartridge Box Unit to the full to its base. (See
Fig. 4-73.)
Make sure to align the positioning hole (x1) on the Cartridge
Box Unit with the dowel (x1) of the Base Frame when
reassembling them. (See
Fig. 4-82.)
When installing the Cartridge Box Unit, make sure to secure
the hooks (x2) on the Main Frame to their positioning holes
(x2). (See
Fig. 4-82.)
Figure 4-82. Installing the Cartridge Box Unit
Make sure to attach the grounding plate to the place shown in
Fig. 4-80, and secure it with the screw.
Positioning hole & dowel
Positioning hole & hook
Secure the convex sections (x2) of the Clamp Tube into the hole
of it from outside to inside as shown in
Fig. 4-83.
Fold the wings inward as shown in Fig. 4-83.
Figure 4-83. Installing the Clamp Tube
When installing the Ink Supply IC Holder Assy, make sure to
remove slack around the section B by moving the Carriage Unit
between the 0-digit side and the 80-digit side a few times.
Figure 4-84. Installing the Ink Supply IC Holder Assy
For routing the FFCs, see "4.4 Routing FFC/cables" (p.196).
A D J U S T M E N T
R E Q U I R E D
After removing/replacing the Ink Supply IC Holder Assy, make the
specified adjustments. (See
Chapter 5 "ADJUSTMENT".)
Clamp Tube
Wings of Clamp Tube
Hole on Clamp Tube
Convex of Clamp Tube