EB-S01/W01/X14G/S11/X11/S02/S02H/X02/W02/S12/S12H/X12/W12/X14 EH-TW480
Disassembly and Assembly CONFIDENTIAL
SEIKO EPSON 87 Revision C
3.3.10 EX Duct (assembly)
1. Remove the Air Filter. (p.59)
2. Remove the Lamp. (p.60)
3. Remove the Upper Case (assembly). (p.62)
4. Remove the MA Board (assembly). (p.74)
5. Remove the Optical Engine. (p.82)
6. Remove the two screws.
7. Release the safety switch and remove the EX Duct (assembly).
Figure 3-29.
Standard Operation Time 7 Min.
Set the safety switch with the cable up and also with the print facing the EX Duct
(assembly).
C.B.P-TITE SCREW,2.5X10,F/ZN-3C
Safety Switch
EX Duct
(assembly)