Chapter 1 TD Bridge Overview
1
Error handling
When an error occurs while checking the RJD file or writing data to a disc, the RJD file or INP file is changed to ERR (ERRor) file.
The error code is written to the STF file.
When an error occurs while checking the RJD file or writing/printing data to a disc, the RJD file or INP file is changed to ERR
(ERRor) file. The error code is written to the STF file.
In the case of errors during operation, job error information moves to the log folder after one or two hours, and device error
information remains in the STF file unless the reason for the error is removed. (For more details on STF file, see "STF File" on
page 4-72.)
Registering another job during operation
You can register another job during operation. When a JDF file is created and moved to the monitoring folder using the
cooperative application, preprocessing is performed and the JDF file is changed to RJD file. Then when the preprocessing is
completed, the RJD file is changed to INP file and holds the status until the ongoing job is finished.
Upon completion of the ongoing job, the registered job is automatically started.
The discs are published in the order of registration. Setting the job priority enables jobs registered later to be started earlier.
TD Bridge
EPSON Total Disc Maker
INP
STF
RJD
PRN
Discproducer
ERR
Log folder
Error during
preprocessing
Error during
operation
Disc
image data
Check
as necessary
Error code
is written
Your Cooperative Application
In the same computer
Monitoring Folder
Error during
operation
Error during
preprocessing
TD Bridge
Total Disc Maker
INP1
STF
JDF2 RJD2
PRN
INP2
PRN 2
JDF2
Your Cooperative Application
In the same computer
Monitoring Folder
Error code
is written
Next job becomes INP le
and waits until the
ongoing job is nished
Disc
image data 2
Disc
image data
Write
data 2
Print
data 2
Discproducer